Laboratory shaker

RY-002

General: This shaking apparatus has been developed to meet th shaking process which is one of the conditions of a rep In order to avoid developing a product exclusively to be operated by an electronic unit not only regulation the e the shaking speed in cycles per min. Moreover, the ele through a digital pushbutton system at the front panel t minutes. It is possible to set the shaking speed at digits from ap which is locked to 20 mm Amplitude and cannot immed numerous experiments with determination of bitterness sufficiently heavy shaking with a minimum heating of th Considering the fact that determination of bitterness re been given to the construction of the mechanical syste including a very long life. Consequently, all movable pa secure the motor against too heavy and too many load separated. The driving power is transmitted through a toothed belt including a connecting rod fastened to the motion syste Speed setting: There are three options to set the shaking speed by turning the speed button. VAR: When moving the rotary switch to setting VAR it When moving the rotary switch to setting VAR it is possible to adjust the shaking speed all over the range of measurement by turning the button marked VAR. BITTERNESS: When delivered, the instrument is preset at 600 cycles per min. At this speed the timer must be set to 15 minutes. It is possible to change the must be set to 15 minutes. It is possible to change the preset speed by using a screwdriver - setting marked ADJ.BITTERNESS. X: Also when moving the rotary switch to setting X the speed will be preset and may be adjusted by using a screwdriver - setting marked ADJ.X Note: Above adjustments (ADJ.BITTERNESS and ADJ.X) must be made only when the instrument is turned on and the speed is displayed. The adjusted speed will be stored and will be available also when the load is changed. 

Time Setting: An electronic timer integrated in the instrument is connected or disconnected when switch marked TIMER ON/OFF is activated TIMER ON/OFF is activated. In position OFF the instrument is started by pressing the button marked TIMER START. The instrument will then operate continuously until pushing the switch marked TIMER STOP. In position TIMER ON the shaking time is set at digits of whole minutes from 1 to 99 by pressing the digital switch marked TIMER MIN. In position TIMER ON the instrument is started by pressing the button marked TIMER START. The instrument will operate until the set time is reached and the timer automatical1y disconnects the instrument and reset, ready for next period. It will always be possible to stop the instrument by pressing the button marked TIMER STOP. The timer is simultaneously reset. Loss of power or disconnection of the switch POWER ON will also reset the timer. Instrument operation: Variable speed with timer duration 15 min: speed with timer duration 15 min: 1 Set the timer switch in position ON. 2 Set the digital timer switch at 15 min. by pressing the 3 Set the rotary switch in position VAR. 4 Set the main switch POWER in position ON. 5 Start the instrument by pressing TIMER START. 6 Turn the adjustment button marked VAR until the des the adjustment button marked VAR until the des Bitterness with timer 15 minutes: 1 Set the timer switch in position ON. 2 Set the digital timer switch at 15 minutes by pressing 3 Set the rotary switch in position BITIERNESS. 4 Set the main switch POWER in position ON. 5 Start the instrument by pressing TIMER START X operation without timer: (operates until manual s 1 Set the timer switch in position OFF. 2 Set the rotary switch in position X 3 Set the main switch POWER in position ON 4 Start the instrument by pressing TIMER START. LG-automatic aps , Denmark Timer ON/OFF Timer ON/OFF Timer START Timer START s Shaking time e (+ or - ) buttons above and below the digits. sired speed is displayed sired speed is displayed the buttons (+ or - ) above and below the digits.