Specifications

Cooling Method Air-Cooled Type
Type Temperature and humidity Controller
Cooling Capacity (W) 4500/5200
Heating Capacity (W) 7800
Humidifying Capacity (kg/h) 15.6
Temperature Control Precision (°C) +-0.2
Setting Temperature Range (°C) 20~30
Humidity Control Precision (%RH) +-1.0
Setting Humidity Range (%RH) 40~80
Use Area Temperature (°C) 20 ~ 35 (change in temperature gradient: within 1°C/1h)
Use Area Humidity (%RH) 10 ~ 85 (change in temperature gradient: within 5%/1h) (No condensation)
Processed Air Volume (m2/min)(50Hz) 21/24
External Dimensions(mm) H1481×W650×D1115
Volume (kg) 260
Coating Color Ivory (JPMA: Semi-gloss Y22-85B)
Blower Duct Connection Diameter (mm) φ200 with damper
Rated Voltage (V) Three-phase AC200
Consumption Current (A) 7.5/8.5(MIN) 63.2/64.6(MAX
Wattage (W) 2000/2500(MIN) 21800/22300(MAX)
Humidifier/Water Supply Volume (ℓ/h) 18
Humidifier/Water Supply Pressure (MPa) 0.03-0.5
Water Supply Temperature (°C) 0-50
Humidifier/Water Supply Connection Diameter (mm) 15A female socket (Rc: 1/2 inch)
Drain Discharge Water Connection Diameter (mm) 20A female socket (Rc: 3/4 inch)
Coolant R-407c 1470g
Exhaust Air Volume (m3/min) (Inverter control) 32.5/41.5
Safety Circuit/Main Circuit Earth leakage circuit breaker (75A 30mA)
Safety Circuit/Blower Overcurrent relay (manual reset) (3.3A), Delay timer (3 minutes), Surge Absorber
Safety Circuit/Compressor Overcurrent relay, motor protectors, surge absorbers, low temperature thermostat driving prevention
Safety Circuit/Heater Thermostat to prevent overheating (65°C OFF 55°C ON), thermal fuse (99°C), surge absorber
Safety Circuit/Humidifier Float switch, thermostat to prevent overheating (120°C +- 10 ℃ OFF), fuse temperature (119°C), automatic timer drainage, drainage manual switch, surge absorber
Output/Main Unit Malfunction Output No-voltage contact a (AC250V / 3A / Resistive load)
Output/Temperature Control Top-Bottom Limit Alarm No-voltage contact a (AC250V / 3A / Resistive load)
Output/Humidity Control Top-Bottom Limit Alarm No-voltage contact a (AC250V / 3A / Resistive load)

Dimensions

405_ext_82_en_0_S.png

 

Sensor dimensions

405_ext_85_en_0_S.png

Temperature & Humidity Control Range Chart

405_ext_88_en_0_S.png
Measurement conditions(left table)
(1)AC200V 50Hz three-phase power supply:
(2)25°C ± 1°C / 40 +- 5% RH: ambient temperature and humidity
(3)9m 3 / min: the amount of wind blowing
(4)Sensor, the performance of the outlet duct insulation installed in the degree of bending once 4m90
Measurement conditions (table)
(1)AC200V 50Hz three-phase power supply:
(2)25°C +- 1°C / 50 +- 5% RH: ambient humidity
(3)18m 3 / min: the amount of wind blowing
(4)Sensor, the performance of the outlet duct insulation duct mounting degree of bending once 4m90