Designed specifically for Aquaculture Systems, the YSI 5500D and AquaManager® Software integrate process control, alarming, and data management into one product. Simple enough to monitor one tank, powerful enough to manage a full scale farming operation from anywhere in the world. Simultaneously measure dissolved oxygen with optical technology in multiple tanks or ponds.

 

  • Overview 
  • Specifications 
    Buffer Recognition Yes
    Certifications RoHS, ULC, IP-65, CE, Made in USA, CUL, ETL, NEMA 4X
    Connectivity / Communications Ethernet and wireless optional, RS485 and RS232 standard
    Data Management AquaManager™ Software integrates process control, alarming, and data management into one product
    Desktop Software Compatible Windows 2000/XP/Vista/Windows 7 operating systems, AquaManager®
    Display Back-lit graphic LCD (320 x 240) with timer, extended temperature range LCD
    Equipment used with 40-, 40, 50, 4-, 30-, 20, 10-, 60- or 100-meter cable with optical DO probe/Temp 626320 Sensor Cap (included with initial cable/probe purchase) 5402 Serial to Ethernet Module 5285 RS232 Opto isolator 6505 W, 50-, 60 or 100 1-, 30, 4, 626250-1, 10, 20-
    GLP Compliance Yes
    Logging Capabilities Yes
    Measurement Method / Channels ORP, photo period, 0 to 5.0 V, pH, TGP, etc. (transmitter may be required) 2 user-configurable inputs (digital 0 to 1.0 VDC, 1-4 DO probe inputs depending on model 4 user-configurable inputs for temp or (digital 0 to 1.0 VDC, 0 to 5.0 VDC or 4-20 mA) DO
    Memory Non-volatile, 2000 data, 1250 relay/alarm, 1000 entries/change and 500 GLP records
    Monitoring Yes
    Operating Temperature -15 to +70°C (5 to 158°F), direct outside conditions with NEMA 4X enclosure
    Parameters Measured Dissolved Oxygen % Saturation, Dissolved Oxygen mg/L, Temperature (optional)
    Power 100-240 VAC, automatically switches to 12 VDC back-up with alarm if primary voltage drops
    User Calibratable Yes
    User Replaceable Yes
    Warranty 2-years instrument; 1-year probes and cable
    Waterproof Yes
    Specification  
    Timers 4 timers - 10 events cascading events start/duration
    4 feed timers (feeders not included); Feed Smart software manages feed delivery, user-selectable inputs for number of daily feedings, daily feed weights, total biomass, FCRS and parameter control
    Inputs 1-4 DO probe inputs depending on model
    4 user-configurable inputs for temp or (digital 0 to 1.0 VDC, 0 to 5.0 VDC or 4-20 mA) DO, pH, TGP, ORP, photo period, etc. (transmitter may be required)
    2 user-configurable inputs (digital 0 to 1.0 VDC, 0 to 5.0 VDC or 4-20 mA) DO, pH, TGP, ORP, photo period, etc. (transmitter may be required)
    Output Relays 8 each 10 amp 115 VAC (5 amp 230 VAC) relays for parameter, control and/or alarm
    E-mail and/or SMS alarming up to 3 e-mails with Ethernet module or up to 10 e-mails with AquaManager
    Field Upgradeable Software​ Yes; flash based
    Height 6.5 in, 16.5 cm
    Length 8.5 in, 21.6 cm
    Depth 4.75 in, 12.1 cm
    Optical Sensor - Diameter 0.95 in, 2.4 cm
    Optical Sensor - Length 7.5 in, 19 cm
    Parameter
    (units)
    Range Accuracy Resolution
    Dissolved Oxygen*
    (% saturation)
    0 to 500% 0 to 200%: ±1% of reading or ±1% air sat, whichever is greater;
    200 to 500%: ±10% of reading
    0.1% air saturation
    Dissolved Oxygen*
    (mg/L)
    0 to 50 mg/L 0 to 20 mg/L: ± 0.1 mg/L or ±1% of reading, whichever is greater;
    20 to 50 mg/L: ±10% of reading
    0.01 mg/L or 0.1 mg/L (auto-scaling)
    Temperature
    (°C, °F)
    0 to +45°C (32 to 113°F) ±0.2°C 0.1°C

    *Optical dissolved oxygen sensor. 

    Specifications indicate typical performance and are subject to change.