Compact Readout Unit MODEL CR-400
The CR-400 readout unit, when connected to your mass flow control-ler or meter with a cable, provides the key mass flow functions, such as flow measurement and control as well as cumulative flow calcula-tions and flow event outputs. This readout unit offers RS-485 commu-nications capability, so multiple readout units can be controlled online by a host computer. * The CR-400 is fully compatible in size with the CR-300.
Features
・Total flow is displayed in 8 digits: The upper 4 digits and the lower 4 digits are shown alternately.
・Various event outputs are available.
・With a width of 73 mm and height of 73 mm, it takes up little space.
・Equipped with forced open/close operation of mass flow controller valve.
・External control terminals are provided on the rear for remote control.
・Mass flow control by RS-485 communications
・A lock key prevents accidental operation.
・Mass flow power: ±15 VDC (300 mA)
・Mass flow power: ±15 VDC (300 mA)
Standard Specifications
Mass flow control | Flow setting, forced valve open/close operation and zero cut |
Mass flow input/output | 0–5 VDC |
Mass flow power | ±15 VDC (300 mA) |
Number of display digits | Instantaneous flow: 4 digits, total flow: 8 digits (upper and lower 4 digits shown alternately) |
Display accuracy | Instantaneous flow: Within ±0.1% F.S. ±1 digit |
External control | Rear input terminal: Analog signal and RS-485 (half-duplex) |
Event output | 2 outputs (selected from instantaneous upper limit, instantaneous lower limit, instantaneous upper/lower limits, and set total) Open collector output (max. rating: 50 V, 50 mA) |
Power consumption | Approx. 25 W |
AC power supply | 85–264 VAC, 48–440 Hz |
Weight and dimensions | Approx. 400 g, 73 W × 73 H × 119.5 D mm |