Berthold Vietnam, CONGAUGE LB 6755, CONGAUGE LB 6755 Berthold Vietnam, đại lý Berthold Vietnam
CONGAUGE LB 6755 is a modern, high-tech radiometric detector, utilizing first-class sensing technology to continuously measure both the liquid steel level and the thickness of the casting powder layer in a mold during continuous casting.
The Radiometric Level Measurement Detector CONGAUGE LB 6755 has been designed in cooperation with SMS Concast and enables also for controlling of automatic feeders for casting powder, reducing human intervention in a dangerous area.
CONGAUGE LB 6755 – Your advantages at a glance:
• Measures the steel level and the powder level simultaneously
• Mechanically compatible with LB 6652/6752 installations
• Compatible with LB 452 castXpert
• State-of-the-art SiPM technology
• Automatic calibration rig for steel and powder level supplied
• Superior safety with automatic detection and compensation if a scintillation failure should occur
CONGAUGE LB 6755
Mechanics
|
|
Housing Material
|
Stainless steel 1.4301 (ANSI 304)
|
Weight
|
9 .8 kg (Including adapter flange and hoses)
|
IP-class
|
IP 66 / IP 67
|
Humidity
|
Max. 99%
|
Operating Temperature
|
-20...+55°C (-4...131°F) Sensor internal temperature
|
Storage Temperature
|
-20...+70°C (-4...158°F)
|
Cooling Water
|
Water inlet pressure of max. 6 bar
Water inlet temperature of max. 50°C
|
Electrical Information
|
|
Power
|
24 (18...36) VDC, 6 W
|
Output Signals
|
Digital (RS485) and analogue pulse output
|
Cable |
6 wires, max. 1.5 mm2, shielded, length max. 200 m. |
Logging |
All relevant detector data can be logged in the control unit (LB 452). |
Performance |
|
Scintillators |
10 x NaI(Tl)-crystals; 40 mm x 45 mm x 14 mm |
Gain |
Each scintillator is individually gain stabilized, meaning no
temperature or aging effect. |
Internal Cycle Time |
5 ms standard steel level
500 ms for powder level |
Damping |
0.1 ... 99 s |
Stability |
At constant count rate 1% |
Approvals |
Shock according to ISO 13628-6 (Q1)
Vibration according to ISO 13628-6 11.5.2.2, and CE certification |
Redundancy |
Fourfold calculation of the level value and result verification
for maximal performance.
A scintillation module failure is automatically detected