Ultrasonic Flow Meter For Fuel Gas Control-Máy đo lưu lượng siêu âm Đối với kiểm soát khí đốt nhiên liệu
Xuất sứ: JAPAN
Nhà cung cấp: Pitesco Việt Nam
Hãng sản xuất: AICHI TOKEI
Features
No straight pipe section required for installation
It is possible to connect the flow meter directly to a bend such as an elbow piece and a flexible pipe.
As wide as a 1:50 turn down ratio
Applicable also for measuring gas flow of a burner having a large turn down ratio.
Easy to replace batteries
Users can replace batteries without removing the meter from the piping.
Strong against dust, and high durability
Use the product in such a condition that does not allow the gas to re-liquefy into oil mist.
IP64 Protection – available for outdoor use
High temperature can cause the electronic circuit board to be deteriorated and batteries to be consumed. To avoid unnecessary rise in temperature, the product is recommended to be fitted with a sunshade.
Specifications
Model | UX40 | UX50 | UZ40 | UZ50 | |
---|---|---|---|---|---|
Pipe connection | Screw | Flange | |||
Rc1・1/2 (40A) | Rc2 (50A) | JIS10K 40A Flange (1・1/2″) | JIS10K 50A Flange (2″) | ||
Maximum working pressure | 100kPa | 500kPa | |||
Gas type ※1 | City gas (13A), butane (butane = 70%, propane = 30%), propane (propane = 98%, butane 2%), nitrogen and argon | ||||
Power/ consumption |
Battery ※2 | Exclusive lithium battery (life = 5 years @20℃ and 65%RH) | |||
AC power | 100VAC±15%/max 10W (for 22mA) | ||||
DC power | 24VDC±10%/max 2W (for 26.4V and 22mA) | ||||
Flow range (Actual flow) |
City gas, nitrogen and argon | 1.6~80m³/h | 3~150m³/h | 1.6~80m³/h | 3~150m³/h |
Butane and propane | 3~80m³/h | 3~80m³/h | |||
Accuracy ※3 | ±4%RD (for a range of 10% to 100% of the max flow) ±0.5%FS (for a range of 2% to 10% of the max flow) |
||||
Temperature and pressure compensation ※4 | Yes/No (Normal/Standard conversion) | ||||
Conversion accuracy | ±1.5%RD(@23℃ and 100kPa) | ±1.5%RD(@23℃ and 500kPa) | |||
Display | Main display | Accumulated flow (actual flow: 8-digit integer + 2 decimal places, converted flow: 8-digit integer + one decimal place, accumulated flow of trip function) Alarm indication (for ultrasonic sensor, temperature sensor, pressure sensor, external memory and power voltage (for battery operation only)) |
|||
Sub display | Instantaneous flow: 5 digits; temperature: 3 digits; and pressure: 5 digits | ||||
Output | Analogue | (For 100VAC or 24VDC only) 4-20mADC (load resistance = max 400Ω): choose among options of instantaneous flow, temperature and pressure (default = instantaneous flow) | |||
Pulse | Nch open-drain output (maximum load 24VDC, 50mA) Output 1 (accumulated flow volume pulse): standard = 1000L/P (choose 10, 100, 1000 or 10000 L/P): duty = 20 – 80% Output 2 (alarms): upper & lower limits, or upper limits of accumulated flow (for 100VAC or 24VDC drive); low voltage, or upper & lower limits (for battery drive) |
||||
Communication ※5 | (For 100VAC or 24VDC drive) RS485 Modbus/RTU (4800/9600 bps) | ||||
Fluid temperature | -10℃ to +60℃, under unfrozen condition | ||||
Ambient working temperature and humidity | -10℃ to +60℃, max 90%RH, no condensation permissible | ||||
Protective structure | Indoor and outdoor use *6, IP64 (JIS C 0920) | ||||
Mass | Approximate 4.7kg | Approximate 6.3kg | Approximate 7.0kg | Approximate 8.8kg |
*1 Gas type (composition) can be changed on site among those specified here with little degradation in measuring accuracy.
*2 Replaceable without removing the meter from the piping
*3 In case a distance from an elbow of minimum 10D in the upstream side and 5D in the downstream side of the meter can be secured: ±2%RD (for a range of 10% to 100% of the max. flow) and ±0.5%FS (for a range of 2% to 10% of the max. flow).
The distance to a governor should be greater than 10D for both the upstream and downstream sides of the meter. Failing to meet this condition may lead to inaccurate measurements. For other conditions for installation, please contact us.
*4 Normal flow: Conversion of measurement into a flow at 0℃ and 1atm. Standard flow: Conversion of measurement into a flow at the reference temperature and 1atm
*5 For communication specifications, see our company’s website to download it.
*6 High temperatures can cause the electronic circuit board to be deteriorated and the batteries to be consumed. To avoid unnecessary rise in temperature, the product is recommended to be fitted with a sunshade.
External dimension - UX
Model | L | H | W | h | Connection diameter |
---|---|---|---|---|---|
UX40 | 170 | 212 | 118 | 157 | Rc1・1/2 (40A) |
UX50 | 200 | 227 | 123 | 165 | Rc2 (50A) |
External dimension - UZ
Model | L | H | h | Connection diameter |
---|---|---|---|---|
UZ40 | 200 | 222 | 157 | JIS10K 40A Flange (1・1/2″) |
UZ50 | 220 | 238 | 165 | JIS10K 50A Flange (2″) |