Application |
Measuring element |
1 x Pt 1000; (to DIN EN 60751, class A) |
Media |
liquids and gases |
Pressure rating [bar] |
300 |
Minimum installation depth [mm] |
12 |
Electrical data |
Operating voltage [V] |
18...32 DC; (cULus - Class 2 source required) |
Current consumption [mA] |
< 50 |
Protection class |
III |
Reverse polarity protection |
yes |
Power-on delay time [s] |
1 |
Integrated watchdog |
yes |
Inputs / outputs |
Number of inputs and outputs |
Number of digital outputs: 1; Number of analog outputs: 1 |
Outputs |
Total number of outputs |
2 |
Output signal |
switching signal; analog signal; IO-Link; (configurable) |
Electrical design |
PNP/NPN |
Number of digital outputs |
1 |
Output function |
normally open / closed; (configurable) |
Max. voltage drop switching output DC [V] |
2.5 |
Permanent current rating of switching output DC [mA] |
250 |
Number of analog outputs |
1 |
Analog current output [mA] |
4...20 |
Max. load [Ω] |
500 |
Analog voltage output [V] |
0...10 |
Min. load resistance [Ω] |
2000 |
Short-circuit protection |
yes |
Type of short-circuit protection |
yes (non-latching) |
Overload protection |
yes |
Measuring/setting range |
Probe length L [mm] |
45 |
Measuring range |
-50...150 °C |
-58...302 °F |
|
Factory setting |
-40...150 °C / -40...302 °F |
Set point SP |
-49.8...150 °C |
-57.6...302 °F |
|
Reset point rP |
-50...149.8 °C |
-58...301.6 °F |
|
Analog start point |
-50...145 °C |
-58...293 °F |
|
Analog end point |
-45...150 °C |
-49...302 °F |
|
In steps of |
|
Resolution |
Resolution of switching output [K] |
0.1 |
Resolution of analog output [K] |
current output: MS / 4096; voltage output: MS / 3561 |
Resolution of display [K] |
0.1 |
Accuracy / deviations |
Switch point accuracy [K] |
± 0,3 + (± 0,1 % MS) |
Precision analog output [K] |
± 0,3 + (± 0,1 % MS) |
Display accuracy [K] |
± 0,3 + (± 0,1 % MS) |
Temperature coefficient [% of the span / 10 K] |
0,1; (In case of deviation from the reference condition 25 ± 5 °C) |
Reaction times |
Dynamic response T05 / T09 [s] |
1 / 3; (according to DIN EN 60751) |
Software / programming |
Parameter setting options |
hysteresis / window; normally open / closed; switching logic; switch-on/switch-off delay; Damping; Display unit |
Interfaces |
Communication interface |
IO-Link |
Transmission type |
COM2 (38,4 kBaud) |
IO-Link revision |
1.1 |
Operating conditions |
Ambient temperature [°C] |
-25...80 |
Storage temperature [°C] |
-40...100 |
Protection |
IP 67 |
Tests / approvals |
EMC |
DIN EN 61000-6-2 |
|
DIN EN 61000-6-3 |
|
|
Shock resistance |
DIN IEC 68-2-27 |
50 g (11 ms) |
|
Vibration resistance |
DIN EN 60068-2-6 |
20 g (10...2000 Hz) |
|
MTTF [years] |
470 |
UL approval |
|
Mechanical data |
Weight [g] |
207 |
Housing |
Compact type for adapter |
Material |
stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC |
Materials (wetted parts) |
stainless steel (1.4404 / 316L); O-ring: FKM 80 Shore A |
Process connection |
threaded connection M18 x 1,5 Internal thread |
Installation length EL [mm] |
45 |
Displays / operating elements |
Display |
Display unit |
2 x LED, green |
Switching status |
LED, yellow |
Measured values |
alphanumeric display, red/green 4-digit |
|
Remarks |
Remarks |
MS = set measuring span |
The values for accuracy apply to flowing water. |
|
Pack quantity |
1 pcs. |
Electrical connection |
Connection |
Connector: 1 x M12; Contacts: gold-plated |