sm-series-samwon-vietnam.png

Sm Series Samwon Vietnam, Sm Series Samwon Viet nam, Sm Series Samwon , Samwon Vietnam , Samwon Viet Nam

Sm Series Samwon

Special feature

  • Conveniently available program control(3Pattern 20segments program control)

  • RS485 transmission: Adoption of a computer communication function as a basic specification up to 1~255 ea, and free provision of a monitoring program(use of 20 ea) for demonstration

  • Multi Input : Thermocouple 5, Thermoscope resistor 1, DC voltage 2, Direct current 1, Sensor input of 14 kinds of humidity sensors, etc.

  • Power failure compensation function : In case of a power failure during program control, the value just before the power failure is memorized and operation is performed after recovery of the power failure.

  • Output current limitation: A function to limit the top/bottom of output current value

  • Slow Start: Protection of equipment by setting a current slow start to the device subject to damage of the equipment due to generation of excessive currents as soon as the power is turned ON when using a current output

  • Remote : Control of this product under the same condition as other products by receiving SV values from other products

  • 10 kinds of alarm functions

  • Manual current output : Outputting of currents continuously by designating an arbitrary currnet value

  • 10 kinds of alarms

  • Multi output : Electric current 2, Relay output  3, SSR output 1

Power Supply
  • 100~240AC(power range +10%)

Input

  • Thermocouple : K, J, R, T, C

  • Thermoscope resistor : DIN PT

  • Direct currentElectric current , voltage : 4-20mA, 1-5V, 0-10V

  • Humidity Sensor input

OUT1 | Main output
  • A relay output 
    · Contact capacity : 250V AC5A, 30V DC5A
    · Contact constituent : 1C
    · Control system : PID Control(setting up direction/inverse ), ON/OFF Control(setting up direction/inverse )

OUT2 | Auxiliary outputting based on alarms
  • A relay output
    · Contact capacity : 250V AC2A, 30V DC2A
    · Contact composition : 1A
    · Control method : ON/OFF control(setting up direction/inverse,Operated separately from OUT1)
    · 10 kinds of alarm outputs

OUT3 | Auxiliary outputting based on alarms
  • A relay output    · Same as OUT2

OUT4 | Electric current Main output
  • SSR OUT

  • Electric current output   · DC4-20mA Electric current , 1~5V Power control(setting up direction/inverse, Solw start, with a built in limit function of output upper and lower )

  • Transmission output    · DC4-20mA transmission output(SV transmission output, PV transmission output)

OUT5 | Electric current auxiliary output
  • Electric current output  · DC4-20mA Electric current, 1~5V Power control (setting up direction/inverse, Solw start, with a built in limit function of output upper and lower )

  • Transmission output   · DC4-20mA transmission output(SV transmission output, PV transmission output)

  • COPY control : Controlled in the same way as the current control of output 4

SIZE
  • SM-960N   ·Dimensions : W96×H96×L107 ·Panel size : W92×H92

  • SM-940N   ·Dimensions : W96×H48×L107 ·Panel size : W92×H45

  • SM-490N   ·Dimensions : W48×H96×L107 ·Panel size : W45×H92