Application |
Application [m] |
0.03...0.3 |
Electrical data |
Operating voltage [V] |
10...30 DC; (cULus - Class 2 source required) |
Current consumption [mA] |
30 |
Current consumption reference voltage [V] |
24 |
Protection class |
III |
Reverse polarity protection |
yes |
Type of light |
red light |
Wave length [nm] |
650 |
Typ. lifetime [h] |
50000 |
Outputs |
Electrical design |
PNP |
Output function |
2 x normally open / normally closed; (configurable) |
Permanent current rating of switching output DC [mA] |
100; (per output) |
Type of short-circuit protection |
yes (non-latching) |
Overload protection |
yes |
Monitoring range |
Max. light spot width [mm] |
3 |
Max. light spot height [mm] |
3 |
Light spot dimensions refer to |
at maximum range |
Background suppression [m] |
0.03...19.2 |
Measuring/setting range |
Measuring range [m] |
0.025...0.3 |
Sampling rate [Hz] |
33 |
Interfaces |
Communication interface |
IO-Link |
Transmission type |
COM2 (38,4 kBaud) |
IO-Link revision |
1.1 |
SDCI standard |
IEC 61131-9 |
IO-Link device ID |
00 03 F4 / 1012 |
Profiles |
Smart Sensor: Sensor Identification; Binary Data Channel; Process Value; Sensor Diagnosis |
SIO mode |
yes |
Required master port class |
A |
Process data analogue |
2 |
Process data binary |
2 |
Min. process cycle time [ms] |
6 |
Operating conditions |
Ambient temperature [°C] |
-25...50 |
Note on ambient temperature |
In ambient temperatures < -10 °C a warm-up time is necessary. |
Laser is off. |
|
Storage temperature [°C] |
-30...80 |
Protection |
IP 65; IP 67 |
Tests / approvals |
EMC |
|
Laser protection class |
1 |
Notes on laser protection |
Caution: |
Laser light |
laser class: |
1 |
|
EN / IEC60825-1:2007 |
|
EN / IEC60825-1:2014 |
|
Complies with 21 CFR 1040 except for deviations pursuant to Laser Notice No. 50, dated June 2007. |
|
MTTF [years] |
181 |
Mechanical data |
Weight [g] |
205 |
Dimensions [mm] |
61.7 x 22.5 x 45.2 |
Material |
Housing: stainless steel (1.4404 / 316L); PPSU; ABS; PMMA; PBT PC; EPDM; front lens: glass |
Displays / operating elements |
Display |
Switching status |
2 x LED, yellow |
|
1 x alphanumeric display, 3-digit |
|
Accessories |
Accessories (supplied) |
|
Remarks |
Remarks |
cULus - Class 2 source required |
|
Pack quantity |
1 pcs. |
Electrical connection |
Connection |
Connector: 1 x M12 |
Diagrams and graphs |
Hysteresis graph |
x: |
distance sensor/object [mm] |
y: |
min. distance object/background [mm] |
1 = |
background (black 6 % remission) |
2 = |
background (white 90 % remission) |
|
|
a: |
sensor |
b: |
object |
c: |
background |
x: |
distance sensor/object [mm] |
y: |
min. distance object/background [mm] |
|
Other data |
Parameter |
Setting range |
Factory setting |
Uni |
mm, inch |
mm |
OU1 |
Hno, Hnc, Fno, Fnc, OFF |
Hno |
SP1 [mm] |
30...300 |
300 |
nP1 [mm] |
30...300 |
90 |
FP1 [mm] |
30...300 |
110 |
OU2 |
Hno, Hnc, Fno, Fnc, OFF |
Hno |
SP2 [mm] |
30...300 |
30 |
nP2 [mm] |
30...300 |
190 |
FP2 [mm] |
30...300 |
210 |
dS1 [s] |
0...0.1...5 |
0 |
dr1 [s] |
0...0.1...5 |
0 |
dS2 [s] |
0...0.1...5 |
0 |
dr2 [s] |
0...0.1...5 |
0 |
dFo [s] |
0...0.1...5 |
0.1 |
dIS |
ON / OFF |
ON |
|
Repeatability: 6 σ |
|
Repeatability of the measured values |
|
distance |
white (90 % remission) |
black (6 %...90 % remission) |
25...300 mm |
2.0 mm |
5.0 mm |
|
The values apply at |
|
Extraneous light on the object |
< 10 klx |
constant ambient conditions |
23 °C / 960 hPa |
minimum power-on time in minutes |
10 |
|