multifunctional-dc-electronic-load-cc-cv-cr-cp.png

PLZ-5W/5WZ Series -NEW-

Multifunctional DC Electronic Load (CC/CV/CR/CP) : 11 Models

Model

Specification

PLZ205W 

DC Electronic Load: Max. 200 W, 1–150 V, 40 A. Equipped with six modes (Constant Current / Constant Resistance / Constant Voltage / Constant Power / Constant Current + Constant Voltage / Constant Resistance + Constant Voltage) plus Arbitrary I-V Characteristics (ARB) mode to reproduce nonlinear load characteristics. High-speed response with 4 μs start-up time. Sequence control functionality enables actual-load simulations. Parallel operation enables scalability. Comes with LAN, RS-232C and USB communication interfaces installed as a standard feature. *GPIB Option

PLZ405W 

DC Electronic Load: Max. 400 W, 1–150 V, 80 A. Equipped with six modes (Constant Current / Constant Resistance / Constant Voltage / Constant Power / Constant Current + Constant Voltage / Constant Resistance + Constant Voltage) plus Arbitrary I-V Characteristics (ARB) mode to reproduce nonlinear load characteristics. High-speed response with 4 μs start-up time. Sequence control functionality enables actual-load simulations. Parallel operation enables scalability. Comes with LAN, RS-232C and USB communication interfaces installed as a standard feature. *GPIB Option

PLZ1205W 

  DC Electronic Load: Max. 1200 W, 1–150 V, 240 A. Equipped with six modes (Constant Current / Constant Resistance / Constant Voltage / Constant Power / Constant Current + Constant Voltage / Constant Resistance + Constant Voltage) plus Arbitrary I-V Characteristics (ARB) mode to reproduce nonlinear load characteristics. High-speed response with 4 μs start-up time. Sequence control functionality enables actual-load simulations. Parallel operation enables scalability. Comes with LAN, RS-232C and USB communication interfaces installed as a standard feature. *GPIB Option

PLZ2405WB 

 Booster unit for PLZ1205W: Max. 2400 W, 1–150 V, 480 A. Able to connect up to four PLZ2405WB units in parallel to each PLZ1205W master unit (max. 10.8 kW, 2160 A). (Dedicated booster for PLZ1205W. Unable to connect to other models.)

PLZ6005W SR 

 Large-capacity electronic load assembled with PLZ1205W and booster using dedicated rack parts. 6000 W, 1–150 V, 1200 A. Comes with digital interfaces (LAN, USB and RS-232C) as a standard feature. Capable of operation using the Sequence Creation software “Wavy.”

PLZ10005W SR 

 Large-capacity electronic load assembled with PLZ1205W and booster using dedicated rack parts. 10.8 kW, 1–150 V, 2160 A. Comes with digital interfaces (LAN, USB and RS-232C) as a standard feature. Capable of operation using the Sequence Creation software “Wavy.”

PLZ15005W SR 

Large-capacity electronic load assembled with PLZ1205W and booster using dedicated rack parts. 15.6 kW, 1–150 V, 2160 A. Comes with digital interfaces (LAN, USB and RS-232C) as a standard feature. Capable of operation using the Sequence Creation software “Wavy.”

PLZ20005W SR 

  Large-capacity electronic load assembled with PLZ1205W and booster using dedicated rack parts. 20.4 kW, 1–150 V, 2160 A. Comes with digital interfaces (LAN, USB and RS-232C) as a standard feature. Capable of operation using the Sequence Creation software “Wavy.”

PLZ205WZ (SPEC21192) -NEW-

DC load device with impedance measurement function in PLZ - 5W series. DC Electronic Load: Max. 200 W, 1–150 V, 40 A. Impedance measurements are made during discharge, allowing for real-time measurement of impedance values from the DUT. Capable of R, jX, θ, and Z measurements. Measures AC frequency from 100 Hz - 10 kHz (seven fixed settings) and signal levels can be set arbitrarily. Equipped with a voltage slope correction function that minimizes the effect of voltage slope during during battery discharge tests. Zero adjustment function allows for increased accuracy during critical impedance measurements. Measurement results and graphical information can be copied directly from the application software to programs like Excel. 

PLZ405WZ (SPEC21192) -NEW-

DC load device with impedance measurement function in PLZ - 5W series. DC Electronic Load: Max. 400 W, 1–150 V, 80 A. Impedance measurements are made during discharge, allowing for real-time measurement of impedance values from the DUT. Capable of R, jX, θ, and Z measurements. Measures AC frequency from 100 Hz - 10 kHz (seven fixed settings) and signal levels can be set arbitrarily. Equipped with a voltage slope correction function that minimizes the effect of voltage slope during during battery discharge tests. Zero adjustment function allows for increased accuracy during critical impedance measurements.Measurement results and graphical information can be copied directly from the application software to programs like Excel. 

PLZ1205WZ (SPEC21192) -NEW-

DC load device with impedance measurement function in PLZ - 5W series. DC Electronic Load: Max. 1200 W, 1–150 V, 240 A. Impedance measurements are made during discharge, allowing for real-time measurement of impedance values from the DUT. Capable of R, jX, θ, and Z measurements.Measures AC frequency from 100 Hz - 10 kHz (seven fixed settings) and signal levels can be set arbitrarily. Equipped with a voltage slope correction function that minimizes the effect of voltage slope during during battery discharge tests. Zero adjustment function allows for increased accuracy during critical impedance measurements. Measurement results and graphical information can be copied directly from the application software to programs like Excel.