Industrial Style Mass Flow Meter for High Gas Flow
Xuất sứ: Holland
Nhà cung cấp: Pitesco
Hãng sản xuất: Bronkhorst
IN-FLOW 'HIGH-FLOW' F-116BI
Industrial Style Mass Flow Meter for High Gas Flow
· High accuracy, excellent repeatability
· Pressure rating 100 bar
· Virtually pressure and temperature independent
· Compact design
· Rugged, weatherproof housing (IP65, dust and waterproof)
Industrial Style Gas Mass Flow Meters for high flow rates
Bronkhorst® model F-116BI Mass Flow Meters (MFMs) are suited for precise measurement of flow ranges between 1…50 m3n/h and 10…500 m3n/h at operating pressures up to 100 bar. The MFM consists of a thermal mass flow sensor and a microprocessor based pc-board with signal and fieldbus conversion and a PID controller for optional mass flow control by means of a separately mounted control valve. The IN-FLOW model is of rugged design (IP65) for use in industrial environments or even Zone 2 hazardous areas, with optional ATEX Cat. 3 approval.
IN-FLOW series are equipped with a digital pc-board, offering high accuracy, excellent temperature stability and fast response. The main digital pc-board contains all of the general functions needed for measurement and control. In addition to the standard RS232 output the instruments also offer analog I/O. As an option, an on-board interface can be mounted to provide DeviceNet™, PROFIBUS DP, Modbus or FLOW-BUS protocols.
Technical specifications
Measurement / control system |
|
---|---|
Accuracy (incl. linearity) |
±1% FS |
Turndown |
1:50 |
Multi fluid capability |
storage of max. 8 calibration curves |
Repeatability |
< 0,2% Rd |
Response time |
typical: 0,5 seconds |
Operating temperature |
-10…+70°C; |
Temperature sensitivity |
zero: < 0,05% FS/°C; span: < 0,05% Rd/°C |
Pressure sensitivity |
0,1% Rd/bar typical N2; 0,01% Rd/bar typical H2 |
Leak integrity, outboard |
tested < 2 x 10-9 mbar l/s He |
Attitude sensitivity |
max. error at 90° off horizontal 0,2% FS at 1 bar, typical N2 |
Warm-up time |
30 min. for optimum accuracy |
Mechanical parts |
|
---|---|
Material (wetted parts) |
stainless steel 316L or comparable |
Pressure rating |
100 bar abs |
Process connections |
compression type or face seal couplings |
Seals |
standard: Viton®; options: EPDM, Kalrez® (FFKM) |
Weight |
8,0 kg |
Ingress protection (housing) |
IP65 |
Electrical properties |
|||
---|---|---|---|
Power supply |
+15…24 Vdc |
||
Max. power consumption Meter |
Supply |
at voltage I/O |
at current I/O |
Max. power consumption Controller |
Supply |
at voltage I/O |
at current I/O |
PROFIBUS DP |
add 53 mA (15 V supply) or 30 mA (24 V supply) |
||
DeviceNet™ |
add 48 mA (24 V supply) |
||
Analog output/command |
0...5 (10) Vdc or 0 (4)…20 mA (sourcing output) |
||
Digital communication |
standard: RS232; |
Electrical connection |
|
---|---|
Analog/RS232 |
8 DIN (male); |
PROFIBUS DP |
bus: 5-pin M12 (female); |
Devicenet™ |
5-pin M12 (male); |
FLOW-BUS/Modbus-RTU/ASCII |
5-pin M12 (male) |