Application |
Application |
for industrial applications |
Media |
water |
Medium temperature [°C] |
-10...90 |
Pressure rating [bar] |
12 |
Note on pressure rating |
|
MAWP (for applications according to CRN) [bar] |
4.8 |
Electrical data |
Operating voltage [V] |
18...30 DC |
Current consumption [mA] |
< 30 |
Min. insulation resistance [MΩ] |
100; (500 V DC) |
Protection class |
III |
Reverse polarity protection |
yes |
Power-on delay time [s] |
< 3 |
Inputs / outputs |
Number of inputs and outputs |
Number of digital outputs: 2 |
Outputs |
Total number of outputs |
2 |
Output signal |
switching signal; frequency signal; IO-Link; (configurable) |
Electrical design |
PNP/NPN |
Number of digital outputs |
2 |
Output function |
normally open / closed; (configurable) |
Max. voltage drop switching output DC [V] |
2.5 |
Permanent current rating of switching output DC [mA] |
100 |
Short-circuit protection |
yes |
Overload protection |
yes |
Measuring/setting range |
Measuring range |
2...40 l/min |
0.12...2.4 m³/h |
|
Display range |
0...48 l/min |
0...2.88 m³/h |
|
Resolution |
|
Set point SP |
2.4...40 l/min |
0.14...2.4 m³/h |
|
Reset point rP |
2...39.6 l/min |
0.12...2.38 m³/h |
|
Frequency end point, FEP |
8...40 l/min |
0.48...2.4 m³/h |
|
In steps of |
|
Frequency at the end point FRP [Hz] |
100...1000 |
Measuring dynamics |
1:20 |
Temperature monitoring |
Measuring range [°C] |
-10...90 |
Display range [°C] |
-30...110 |
Resolution [°C] |
0.5 |
Set point SP [°C] |
-9...90 |
Reset point rP [°C] |
-10...89 |
In steps of [°C] |
0.5 |
Frequency start point, FSP [°C] |
-10...70 |
Frequency end point, FEP [°C] |
10...90 |
Frequency at the end point FRP [Hz] |
100...1000 |
Accuracy / deviations |
Flow monitoring |
Accuracy (in the measuring range) |
± 2 % MEW |
Repeatability |
± 0,5 % MEW |
Temperature monitoring |
Accuracy [K] |
± 1 |
Reaction times |
Flow monitoring |
Response time [s] |
1; (dAP = 0) |
Damping for the switching output dAP [s] |
0...5 |
Temperature monitoring |
Dynamic response T05 / T09 [s] |
T09 = 6 |
Software / programming |
Parameter setting options |
hysteresis / window; normally open / closed; switching logic; Frequency output; switch-on/switch-off delay; Damping; Display unit |
Interfaces |
Communication interface |
IO-Link |
Transmission type |
COM2 (38,4 kBaud) |
IO-Link revision |
1.1 |
SDCI standard |
IEC 61131-9 |
IO-Link device ID |
488 d / 00 01 E8 h |
Profiles |
Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
SIO mode |
yes |
Required master port class |
A |
Process data analogue |
2 |
Process data binary |
2 |
Min. process cycle time [ms] |
3 |
Operating conditions |
Ambient temperature [°C] |
0...60 |
Note on ambient temperature |
medium temperature < 80 °C |
medium temperature < 90 °C: 0...50 °C |
|
Storage temperature [°C] |
-20...80 |
Protection |
IP 65; IP 67 |
Tests / approvals |
EMC |
DIN EN 61000-6-2 |
|
DIN EN 61000-6-3 |
|
|
Shock resistance |
DIN EN 60068-2-27 |
5 g (11 ms) |
|
Vibration resistance |
DIN EN 60068-2-6 |
with water / 10...50 Hz 1 mm |
|
with water / 50...2000 Hz 2 g |
|
MTTF [years] |
342 |
UL approval |
|
Pressure equipment directive |
sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data |
Weight [g] |
440 |
Material |
stainless steel (1.4404 / 316L); PC; PBT+PC-GF30; PPS; TPE-U |
Materials (wetted parts) |
stainless steel (1.4404 / 316L); ETFE; PA 6T; PPS; FKM |
Tightening torque [Nm] |
30 |
Process connection |
threaded connection G 1/2 DN10 |
Remarks |
Remarks |
MW = Measured value |
MEW = Final value of the measuring range |
|
Pack quantity |
1 pcs. |
Electrical connection |
Connection |
Connector: 1 x M12; Contacts: gold-plated |