Easy to operate Hydrogen Sulphide Analyzers GPR-7500 and GPR-7100
Nhà cung cấp: Pitesco Việt Nam
Hãng sản xuất: AII
Easy to operate Hydrogen Sulphide Analyzers
GPR-7500 and GPR-7100
Features of Easy to operate Hydrogen Sulphide Analyzers
- ATEX & UL certified variants
- Accurate to < 2% of scale with an LDL of 0.1 ppm H2S
- Dedicated sample handling systems are included
- Optional liquid drain system (for entrained liquids)
- 24 month typical sensor life (simple to exchange)
- Easy to use HMI for set-up, operation and field calibration
Technical Specifications
7100 | 7500 IS | 7500 IS -LD | 7500 AIS | 7500 AIS LD | 7500 AIS-S | 7500 IS-S | |
---|---|---|---|---|---|---|---|
Measurement range | 0-20, 0-50, 0-100 ppm | 0-20, 0-50, 0-100 ppm (standard ranges) 0-500, 0-1000, 0-2000 ppm (optional ranges) |
0-20, 0-50, 0-100 ppm | ||||
Accuracy | ±2% of selected range at constant conditions | ||||||
Response time | T90 < 60 seconds | ||||||
Sensitivity (LDL) | 0.1 ppm | ||||||
Linearity | <2% of scale | ||||||
Sensor model | OSV-72-7HH-LM (standard ranges) | OSV-72-7HH (standard ranges), OSV-72-7HH-LD OSV-72-7H (up to 2000 ppm), OSV-72-7H-LD |
OSV-72-7HH-LM (standard ranges) | ||||
Sensor life 25ºC (77°F) and 1 atm | 24 months | ||||||
Calibration interval | 1-3 months - see manual for individual models | ||||||
Inlet pressure | 0.34-2 barg (5-30 psig); vent - atmospheric | atmospheric | |||||
Sample flow rate | 0.5 l/m (1 SCFH) | None, measures H2S in ambient air | |||||
Auxilary air flow rate | 0.5 l/m (1 SCFH) 1.5 Nl/m (3 SCFH) for high range sensor Instrument air required: regulated to 1 barg if internal pump not supplied |
||||||
Gas connections | 1/8" Compression Type Fittings | 1/4" Sample/Span; 3/8" Vent line. | None | ||||
Wetted parts | Stainless steel | ||||||
Display | Graphical LCD 7 x 3.5cm (2.75 x 1.375"); resolution 0.1 ppm | ||||||
Enclosure | Painted aluminum NEMA 4X, 10.1 x 22.9 x 7.6cm (4 x 9 x 3") | NEMA Type 3R for rain in outdoor applications | Type 3R | ||||
Weight | 3.6kg (8 lbs) | 10 Kg (22 lbs) | |||||
Compensation | Temperature compensated | Temperature not required | Barometric pressure, temperature not required | Temperature not required | |||
Signal output | 0-1V | 4-20 mA or 1-5 V DC | |||||
Alarms | None | Two user configurable alarms: magnetic coil relays rated 3A at 100 V AC, programmable alarm delays, alarm bypass for calibration and system fail alarm | None | ||||
LED indicators | LOW BATT Warning; CHARGE mode | NA | |||||
Operating temperature | -10° to 45°C (14°F to 113°F) | ||||||
Power | Rechargeable battery, 8 hours day duty cycle | 18-28 V DC Transmitter, 12 V DC Pump | 12-28 V DC (UL or ATEX Certified) 110-220 V AC (ATEX Certified) Transmitter, 12 V DC PUMP | 12-28 V DC (UL or ATEX Certified) 110-220 V AC (ATEX Certified) | 18-28 V DC | ||
Area classification | ATEX: II 2 G Ex ib IIB T4 Gb Tamb+5°C to +45°C | UL: United States: UL 1203, UL 913, UL 508 ATEX: ATEX: II 2 G Ex ib IIB T4 Gb Tamb -20°C to +50°C |