Cung cấp năng lượng vị trí nguy hiểm Neeltranl Inc Vietnam, phân phối chính hãng Neeltranl Inc Vietnam
Nhà cung cấp: Pitesco
Hãng sản xuất: Neeltranl Inc Vietnam
Cung cấp năng lượng vị trí nguy hiểm Neeltranl Inc Vietnam, phân phối chính hãng Neeltranl Inc Vietnam
Hazardous Location AC and DC Power Supplies
Added Benefits of Dry, Water or Oil Filled Rectifiers and Transformers Supplied by Neeltran – Robust and Reliable Power to run your 24/7 processes.
Neeltran, designs and builds its own rectifier-transformers and rectifiers. This ability allows us to understand the extreme duty a hazardous location power supply has to perform in extreme environments. This gives our designers the experience to design the highest quality units available.
Neeltran possesses multi-industry, engineering, and manufacturing experience that helps us to be flexible and design products that meet your specific technical and safety requirements.
For the Hazardous market we can design the rectifier to be installed inside the same tank of the transformer. Control cabinet and fuses are positioned in a separate explosion proof box, for easy maintenance and control. Typical uses are for chlorine, chlorate, cathodic protection, impressed current cathodic protection power supply, bleach and any other processes that need hazardous location DC and AC supplies. Whether on an oil rig, oil refinery or any other hazardous location we can build to any standard. We an provide water, oil or air cooled utilizing various certified techniques.
- Conservative Transformer design
- Design to all types of environments
- Based on specifications we can conform to ANSI, IEC,ATEX, IECEx,ABS,Gost-R, Kosha, IEEE,NEMA, CSA, BS, AS, UL, JS, CE etc...
- Design to be installed in all the off shore platform, refinery, or chemical facility. High Efficiency units with low operating temperatures
- Multi-pulse and specialty circuit configurations available
- Superior short circuit withstand
- Latest safety features
- Design to local environment, altitude and cooling conditions with all cooling system types available
Standards not limited to | NEC/ANSI / IEEE / IEC /IEC X/ATEX/GOST-R/KOSHA, UL,CSA | |
---|---|---|
Product Ranges not limited to | CLASS 1, Division 1&2, Groups A,B,C,D,Zone 1&2, GAS Groups IIC,IIB+H2, IIB, IIA. | |
Three-phase supply voltage main by customer | Vac | up to 69,000 |
Three phase voltage on the secondary | Vac | up to 80,000 |
DC Voltage | Vdc | up to 90,000 |
Maximum power | kVA | 25,000 |
Frequency | Hz | 50/60 |
Tap changer | No Load | |
Rectifier Connection | Bridge | |
Pulses | 6 / 12 and more | |
Rectifier power section material | Copper or Aluminum | |
DC Current | Adc | up to 15,000 |
Control card type | Digital or Analog | |
Metering | Shunt | |
Rectifying elements | Thyristors / Diodes | |
Redundancy | N+1 (On demand) | |
Temp class | T3, T4, T5 | |
Transformer Cooling | Water / Air / Oil | |
Transformer Oil Type | Mineral / FR3 / Silicon | |
Installation | Indoor or outdoor | |
Transformer Manufacturer | Neeltran | |
Rectifier Manufacturer | Neeltran | |
Line Up Testing Available | Combined Test at Neeltran Factory |