CLEARPOINT® STERILE & STEAM FILTER
Advantages of CLEARPOINT® sterile and steam filters
Filter housing
- All components comply with FDA CFR Title 21 & EC/1935/2004
- High quality stainless steel, suitable for food contact
- Connection for condensate drain off and venting valves
Sterile filter element
- Germ-free hygiene
- Complies with cGMP requirements
- High dirt retention capacities at low pressure differences
- Maximum separation performance, as at minimum work load
Steam filter element
- High steam quality extends the service life of the sterile filter
- Can be regenerated via reverse flushing and ultrasound
- High through flow rates with low pressure difference
- Also suitable for culinary steam
Technical data steam- and sterile filters
Filter housing
Maximum pressure (bar) installation sizes 60-1920 | 16 bar |
Maximum pressure (bar) installation size 2880 | 12 bar |
Material | Hygienic high-quality stainless steel, polished outer surfaces |
Connection for CLEARPOINT PIF filter housing with flange connection | DN10…DN80 |
Connection for CLEARPOINT PIT, PIW filter housing * with thread, welded-on end | G ¼…G3 |
Sterile filter
Can be utilised up to 180 °C (356 °F) |
Support cylinder and end caps made of stainless steel 1.4301 |
Separation rate ≥ 99.99998% based on ≤ 0.2μm |
Suitable for DC and counter-flow sterilisation and VPHP |
Integrity test according to HIMA |
At least 100 sterilization cycles at 121°C and 30 min of steaming |
Steam filter
Can be utilised up to 180 °C (356 °F) |
Bursting pressure 10 bar (at 20 °C) |
Degree of porosity> 50% |
Double O-ring made of EPDM |
Welded stainless steel end caps for maximum stability |
Seamless filter pipe made of sintered stainless steel |