CAN Stick, Compact measurement system
Hãng sản xuất: GHM Group
SCC1, Imtron Vietnam, GHM Group Vietnam, dai ly hang Imtron tại Việt Nam, etc
CAN Stick
Universal amplifier supported by the Federal Ministry of Economics and Technology based on a resolution by the German Bundestag.
Characteristics
The SIQUAD CAN Stick offers computer-controlled signal conditioning of various sensors. It has 1 DSP per unit
There are 2 versions depending on the sensor requirements. Signal output is digital via CAN. Protocol is CAN 2.0B. Parameter setting is done with the software DaSoft via a USB-to-CAN interface. Signal filtering can be configured from 3..2000 Hz at 20 kS/s sample rate.
Technical Data
General
+ Accuracy : see sensors
+ Channels/unit 1, isolated
+ AD converter 24 bit / channel
+ Sample rate Appr. 20 kHz (51.2 µs)
+ Band width Appr.5 kHz
+ Digital output CAN
+ Input protection ± 100 V, ESD IEC 1000-4-2
+ Supply voltage 9..36 V DC
+ Sensor supply 0.5, 1.0, 2.5, 4 V (50 mA), 24 V (40 mA)
+ Environmental temperature 0..+50 °C
Strain gauge bridges
+ Range 0.5, 1, 2, 4, 5, 10, 25, 50 mV/V
+ Accuracy ± 0.03 %
+ Sensor supply 0.5, 1, 2.5, 4.5 V (> 120 Ω)
+ Type of bridge 4-wire/6-wire : Full/half bridge (> 120 Ω), quarter bridge (120 Ω, 350 Ω)
Voltage
+ Range : 0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 80 V
+ Accuracy ± 0.05 % max.
+ input voltage 80 V
+ Impedance 100 kΩ (> 5 V range)
+ Diff. input yes
Signal current
+ Range ± 20 mA, 4..20 mA
+ Accuracy ± 0.1 %
Current transmitter
+ Sensor supply 24 V (max. 40 mA)
Potentiometer 3-wire conn.
+ Range 6.25, 12.5, 25, 50, 100%
+ ccuracy ± 0.1 %
+ Sensor supply 2.5 V
Thermo couples J,K (others opt.)
+ Range ±100, ±200, -200..+500, -200..+1000 °C
+ Accuracy ± 0.1 % (without CJC)
Pt100
+ Range ±100, ±200, -200..+500, -200..+1000 °C
+ Accuracy ± 0.1 %
CP® sensors
+ Range 1, 2, 5, 10 V min.
+ input frequency appr. 7 Hz
+ Accuracy ± 0.1 %
+ Sensor supply 4 mA, 22 V
Frequency analog
+ Range 5, 10, 20, 50, 100, 200, 500 Hz, 1, 2, 5, 10, 20 kHz
+ Accuracy ± 0.05 %
+ Input voltage ± 0.02.70 V
Frequency digital
+ Range 5, 10, 20, 50, 100, 200, 500 Hz, 1, 2, 5, 10, 20, 50, 100, 200, 500 kHz
+ Accuracy ± 0.05 %
+ Input voltage TTL / CMOS (≥ 3.5 V)
Torque meter, Telemetry (Discriminator)
+ Range: Free entry of mid frequency and stroke, max. 100 kHz
+ Accuracy ± 0.05 %
+ Input voltage TTL / CMOS (≥ 3.5 V)
Incremental encoder
+ Range Variable, set by no. of pulses
+ Accuracy ± 0.05 %
+ Input voltage TTL / CMOS
+ Direction sense/sync without, static, dynamic / with sync, without sync
PWM sensors
+ Range 100 Hz, 1 kHz, 10 kHz
+ Accuracy ± 0.2 %
+ Input voltage TTL / CMOS (≥ 3.5 V