5437a-5437d-5331a-5331d-5333a-5333d-5334a-5334b-5335a-5335d-5337a-2-wire-hart-7-temperature-transmitter-pr-electronics.png

2-wire HART 7 temperature transmitter Pr Electronics , 2-wire HART 7 temperature transmitter Pr Electronics Vietnam , 2-wire HART 7 temperature transmitter Pr Electronics Viet Nam ,

Pr Electronics, Pr Electronics VIetnam , Pr Electronics Viet Nam .

2-wire HART 7 temperature transmitter

  • RTD, TC, potentiometer, linear resistance and bipolar mV input
  • Single or true dual inputs with sensor redundancy and drift detection
  • High accuracy across a wide ambient operating temperature of -50 to +85°C
  • 2.5 kVAC galvanic isolation
  • Full assessment to IEC61508 : 2010 for use in SIL 2/3 applications

Application

  • Temperature measurement of a wide range of TC and RTD types.
  • Conversion of wide span linear resistance and potentiometer inputs.
  • Conversion of bipolar mV signals to 4...20 mA.
  • Integration into asset management schemes.
  • Critical applications requiring superior accuracy and/or sensor redundancy and drift detection.

Technical characteristics

  • True dual input transmitter. High density 7-terminal design accepts the widest range of dual input combinations.
  • Sensor redundancy - output automatically switches to secondary sensor in event of primary sensor failure, maintaining uptime.
  • Sensor drift detection - alerts when sensor differential exceeds user-defined limits, for maintenance optimization.
  • Dynamic variable mapping for process data in addition to the primary variable e.g. dual input features such as average, differential and min./max. tracking.
  • Groundbreaking digital and analog signal accuracy over full input span and ambient conditions.
  • Extensive sensor matching including Callendar Van Dusen and custom linearizations.
  • Programmable input limits and runtime metering ensure maximum process traceability and sensor out of range protection.
  • IEC 61508 : 2010 full certification up to SIL 3 together with enhanced EMC Functional Safety testing to IEC 61236-3-1.
  • Meets NAMUR NE21, NE43, NE44, NE89 and NE107 compliant diagnostics information.

Mounting / installation

  • For DIN form B sensor head mounting.
  • Configuration via standard HART communication interfaces or by PR 5909 Loop Link.
  • The 5437A can be mounted in zone 2 and 22 / Class I, Division 2, Groups A, B, C, D.
 
5437A

2-wire HART 7 temperature transmitter

 

 

  • RTD, TC, Ohm, and bipolar mV input
  • Single or true dual inputs
  • HART 7 and HART 5
 
 
5437D

2-wire HART 7 temperature transmitter

 

 

  • RTD, TC, Ohm, and bipolar mV input
  • Single or true dual inputs
  • HART 7 and HART 5
 
5331A

2-wire programmable transmitter

 

  • RTD, TC, Ohm, or mV input
  • Extremely high measurement accuracy
  • For DIN form B sensor head mounting
 
 
5331D

2-wire programmable transmitter

 

  • RTD, TC, Ohm, or mV input
  • Extremely high measurement accuracy
  • For DIN form B sensor head mounting
 
 
5333A

2-wire programmable transmitter

 

  • RTD or Ohm input
  • High measurement accuracy
  • For DIN form B sensor head mounting
 
 
5333D

2-wire programmable transmitter

 

  • RTD or Ohm input
  • High measurement accuracy
  • For DIN form B sensor head mounting
 
 
5334A

2-wire programmable transmitter

 

  • TC input
  • High measurement accuracy
  • For DIN form B sensor head mounting
 
 
5334B

2-wire programmable transmtitter

 

  • TC input
  • High measurement accuracy
  • For DIN form B sensor head mounting
 
 
5335A

2-wire transmitter with HART protocol

 

  • RTD, TC, Ohm, or mV input
  • HART 5 protocol
  • For DIN form B sensor head mounting
 
 
5335D

2-wire transmitter with HART protocol

 

  • RTD, TC, Ohm, or mV input
  • HART 5 protocol
  • For DIN form B sensor head mounting
 
 
5337A

2-wire transmitter with HART protocol

 

 

  • RTD, TC, Ohm, and bipolar mV input
  • HART 5 and HART®  7
  • Mounting in Safe area or Zone 2/22
 
 
5337D

2-wire transmitter with HART protocol

 

 

  • RTD, TC, Ohm, and bipolar mV input
  • HART 5 and HART 7
  • Mounting in hazardous gas and dust area
 
 
5350A

PROFIBUS PA / FOUNDATION Fieldbus transmitter

 

  • Automatic protocol switch
  • Basic or LAS capability with F.F.
  • For DIN form B sensor head mounting
 
 
5350B

PROFIBUS PA / FOUNDATION Fieldbus transmitter

 

  • Automatic protocol switch
  • FISCO-certified
  • Basic or LAS capability with F.F.