Veris Industries Vietnam, U001-0158, Đồng hồ đo lưu lượng BTU U001-0158, Đại lý chính hãng Veris Industries Vietnam

Đồng hồ đo lưu lượng BTU U001-0158, Đại lý chính hãng Veris Industries Vietnam

 

Series 380 BTU system provides a low-cost system for metering hot and cold systems. The 380 measures flow and temperature differential to accurately calculate energy. With BACnet, Modbus RS-485, or scaled pulse output, it can interface with many existing control systems. The rugged design incorporates an impeller flow sensor and two temperature probes, one mounted in the flow sensor tee and the other on either the supply or return line, depending on the application. Commissioning can be done in the field via a computer connection or set up at the factory. Setup includes energy measurement units, measurement method, communication protocol, pulse output control, fluid density and specific heat parameters.

  • BACnet and Modbus protocols are standard features, easy integration with existing control systems
  • Easy installation - minimal connections, simplify installation, saving time and cost
  • Integration of flow and temperature sensors with metering components, single solution for BTU metering
  • Rugged, compact design with two temperature probes
  • 316 stainless steel impeller with tungsten carbide shaft
  • PEEK sensor tip
  • Polyurethane potting
  • Scaled pulse, open drain output
Application      :      Flow and BTU determination
Communication      :      ModBus (RTU) | BACnet (MS/TP)
Energy Units      :      BTU | kBTU | mBTU | kWh | MWh | kJoules | MJoules | Tons | custom
Field Programmable      :      Yes
Fitting Material      :      Brass | Polymer
Fitting Size      :      2" NPT
Fitting Type      :      Threaded
Flow Measurement Accuracy      :      ±2%
Flow Measurement Range      :      10.5 - 157.3 GPM (40 - 595 LPM)
Flow Measurement Repeatability      :      ±0.5%
Flow Sensor Type      :      Impeller
Measurement Type      :      BTU
Medium      :      Water based liquids
Model      :      3802020-1206
Operating Fluid Temperature      :      20 - 260 °F (-6.7 - 126.7 °C)
Operating Temperature      :      20 - 260 °F (-6.7 - 126.7 °C)
Output Specifications      :      Scaled Pulse
Outputs      :      Protocol Communication | Pulse output
Pipe Material      :      Copper | Polymer | Steel | Stainless Steel
Product Type      :      Sensor
Range      :      380 Series
Standards      :      IEC 751 Class B
Temperature Measurement Accuracy      :      ±0.5%
Temperature Measurement Range      :      20 - 260 °F (-6.7 - 126.7 °C)
Totalizer Quantities      :      1
Totalizer Resettable      :      No
Warranty      :      1 year