Germany Origin |
Bronkhorst Vietnam |
Model key : F-111AC-50K-AGD-22-V |
Mass Flowmeter; Product series : EL-FLOW Select; Ingress Protection : IP-40; Material : SS 316L; Multi Fluid Multi Range : Disabled |
Fluid : N2 (Nitrogen); Flow range : 1...50 ln/min |
Accuracy : ±0.5% Rd plus ±0.1% FS (At calibration conditions) |
Calibration certificate : 3-point calibration |
Inlet pressure (P1) : 2 bar (g); Outlet pressure (P2) : 2 bar (g) |
Temperature : 20...35 °C (calibrated for 27.5 °C) |
Seals : Viton 51415; Inlet connection : 1/4" OD compression type |
Outlet connection : 1/4" OD compression type |
Output signal : RS-232 0...100 % (4...20 mA sourcing) |
Setpoint : RS-232 0...100 % (4...20 mA sinking) |
Power supply : +15...24 Vdc |
100% Germany Origin |
Bronkhorst Vietnam |
Additional calculated curve for |
Fluid : N2 (Nitrogen); Flow range : 3.454E-01...17.27 ln/min |
Inlet pressure (P1) : 2 bar (g); Outlet pressure (P2) : 2 bar (g) |
Temperature : 20...35 °C (calibrated for 27.5 °C) |
Conversion table : 11 points |
Stored in instrument of pos 001 as Fluid 2 |
100% Germany Origin |
Bronkhorst Vietnam |
Swagelok portconnector 1/4x1/4 |
Swagelok portconnector 1/4"x1/4" |
100% Germany Origin |
Bronkhorst Vietnam |
F-004AC Control valve |
Model key : F-004AC-LUU-22-V |
Ingress Protection : IP-40; Fluid : N2 (Nitrogen) |
Flow range : 1...50 ln/min; Inlet pressure (P1) : 2 bar (g) |
Outlet pressure (P2) : 1.6 bar (g); Valve function : Normally Closed |
Orifice : Fixed; Temperature : 20...35 °C; Seals : Viton 51415 |
Plunger : Viton 51415 |
Inlet connection : 1/4" OD compression type |
Outlet connection : 1/4" OD compression type |
100% Germany Origin |
Bronkhorst Vietnam |
F-201AV/F-211AV Mass Flow Controller |
Model key : F-201AV-50K-AGD-22-V |
Product series : EL-FLOW Select; Ingress Protection : IP-40 |
Material : SS 316L; Multi Fluid Multi Range : Disabled |
Fluid : H2 (Hydrogen); Flow range : 1...50 ln/min |
Accuracy : ±0.5% Rd plus ±0.1% FS (At calibration conditions) |
Calibration certificate : 3-point calibration |
Inlet pressure (P1) : 2 bar (g); Outlet pressure (P2) : 1.6 bar (g) |
Valve function : Normally Closed; Orifice : 1.50 mm |
Temperature : 25...35 °C (calibrated for 30 °C) |
Seals : Viton 51415; Plunger : Viton 51415 |
Inlet connection : 1/4" OD compression type |
Outlet connection : 1/4" OD compression type |
Output signal : RS-232 0...100 % (4...20 mA sourcing) |
Setpoint : RS-232 0...100 % (4...20 mA sinking) |
Power supply : +15...24 Vdc |
100% Germany Origin |
Bronkhorst Vietnam |
Additional calculated curve for |
Fluid : H2 (Hydrogen) |
Flow range : 3.524E-01...17.62 ln/min |
Inlet pressure (P1) : 2 bar (g) |
Outlet pressure (P2) : 1.6 bar (g) |
Temperature : 25...35 °C (calibrated for 30 °C) |
Conversion table : 11 points |
Stored in instrument of pos 004 as Fluid 2 |
100% Germany Origin |
Bronkhorst Vietnam |
F-111AC Mass Flow Meter |
Model key : F-111AC-50K-AGD-22-V |
Product series : EL-FLOW Select; Ingress Protection : IP-40 |
Material : SS 316L; Multi Fluid Multi Range : Disabled |
Fluid : CO (Carbon monoxide); Flow range : 1...50 ln/min |
Accuracy : ±0.5% Rd plus ±0.1% FS (At calibration conditions) |
Calibration certificate : 3-point calibration |
Inlet pressure (P1) : 2 bar (g); Outlet pressure (P2) : 2 bar (g) |
Temperature : 25...35 °C (calibrated for 30 °C); Seals : Viton 51415 |
Inlet connection : 1/4" OD compression type |
Outlet connection : 1/4" OD compression type |
Output signal : RS-232 0...100 % (4...20 mA sourcing) |
Setpoint : RS-232 0...100 % (4...20 mA sinking) |
Power supply : +15...24 Vdc |
100% Germany Origin |
Bronkhorst Vietnam |
Additional calculated curve for |
Fluid : CO (Carbon monoxide) |
Flow range : 3.448E-01...17.24 ln/min |
Inlet pressure (P1) : 2 bar (g) |
Outlet pressure (P2) : 2 bar (g) |
Temperature : 25...35 °C (calibrated for 30 °C) |
Conversion table : 11 points |
Stored in instrument of pos 005 as Fluid 2 |
100% Germany Origin |
Bronkhorst Vietnam |
Swagelok portconnector 1/4x1/4 |
Swagelok portconnector 1/4"x1/4" |
100% Germany Origin |
Bronkhorst Vietnam |
F-004AC Control valve |
Model key : F-004AC-LUU-22-V |
Ingress Protection : IP-40; Fluid : CO (Carbon monoxide) |
Flow range : 1...50 ln/min; Inlet pressure (P1) : 2 bar (g) |
Outlet pressure (P2) : 1.6 bar (g); Valve function : Normally Closed |
Orifice : Fixed; Temperature : 25...35 °C |
Seals : Viton 51415; Plunger : Viton 51415 |
Inlet connection : 1/4" OD compression type |
Outlet connection : 1/4" OD compression type |
100% Germany Origin |
Bronkhorst Vietnam |
F-111AC Mass Flow Meter |
Model key : F-111AC-50K-AGD-22-V |
Product series : EL-FLOW Select; Ingress Protection : IP-40 |
Material : SS 316L; Multi Fluid Multi Range : Disabled |
Fluid : Air; Flow range : 1...50 ln/min |
Accuracy : ±0.5% Rd plus ±0.1% FS (At calibration conditions) |
Calibration certificate : 3-point calibration |
Inlet pressure (P1) : 2 bar (g); Outlet pressure (P2) : 2 bar (g) |
Temperature : 25...35 °C (calibrated for 30 °C) |
Seals : Viton 51415 |
Inlet connection : 1/4" OD compression type |
Outlet connection : 1/4" OD compression type |
Output signal : RS-232 0...100 % (4...20 mA sourcing) |
Setpoint : RS-232 0...100 % (4...20 mA sinking) |
Power supply : +15...24 Vdc |
100% Germany Origin |
Bronkhorst Vietnam |
Additional calculated curve for |
Fluid : Air |
Flow range : 3.456E-01...17.28 ln/min |
Inlet pressure (P1) : 2 bar (g) |
Outlet pressure (P2) : 2 bar (g) |
Temperature : 25...35 °C (calibrated for 30 °C) |
Conversion table : 11 points |
Stored in instrument of pos 008 as Fluid 2 |
100% Germany Origin |
Bronkhorst Vietnam |
Swagelok portconnector 1/4x1/4 |
Swagelok portconnector 1/4"x1/4" |
100% Germany Origin |
Bronkhorst Vietnam |
F-004AC Control valve |
Model key : F-004AC-LUU-22-V |
Ingress Protection : IP-40; Fluid : Air; Flow range : 1...50 ln/min |
Inlet pressure (P1) : 2 bar (g); Outlet pressure (P2) : 1.6 bar (g) |
Valve function : Normally Closed; Orifice : Fixed |
Temperature : 25...35 °C; Seals : Viton 51415 |
Plunger : Viton 51415 |
Inlet connection : 1/4" OD compression type |
Outlet connection : 1/4" OD compression type |
100% Germany Origin |
Bronkhorst Vietnam |
BRIGHT B1 IP40 9p SubD |
HI-TEC B1 "Bright" compact local ReadOut/Control module |
IP-40 protection, for mounting on instrument |
Supply voltage 15...24 Vdc |
Suitable for connection to instruments with RS232 I/O-signals |
100% Germany Origin |
Bronkhorst Vietnam |
PiPS-EL Plug-in PS SubD9 |
PiPS-EL Plug-In Power supply |
Input : 100..240 VAC, 50..60Hz |
Sec. Supply : +15 Vdc, max. 0.5A |
Connection : Sub-D9, female |
100% Germany Origin |
Bronkhorst Vietnam |
Cable RS232 Tpart DB9 MBC-II/3 |
RS232 cable (T-part) for IP-40 Mass Flow Controller/Meter |
T-part : Sub-D9 male/female |