Apiste Vietnam, FA Cooler ENC-G1110L, Đại lý chính hãng Apiste Vietnam
Mount Type | Side-mount |
---|---|
Cooling Capacity (W) | 950/1100 |
Setting Temperature Range (°C) | 25 to 45 |
Use Area Temperature (°C) | 20 to 50 |
Use Area Humidity (%RH) | 10-85(No condensation) |
External Dimensions (mm) | H730×W300×D230 |
Volume (kg) | 23 |
Coating Color | Color Munsell 5Y7 / 1 light beige |
Voltage Rating (V) | Single-phase AC100 |
Consumption Current/Rating (A) | 5.5/4.8 |
Consumption Current/MAX (A) | 6.7/6.8 |
Starting Current (A) | 15.6/14.7 |
Consumption Voltage/Rating (W) | 450/470 |
Consumption Voltage/MAX (W) | 620/680 |
Vibration Resistance | Equivalent to JIS Z 0200 Level1 |
Dust & Water Protection Grade | Equivalent to IP54 (internal circulation route) |
Coolant / Filling (g) | HFC-134a 230g |
Noise (dB) | 64/68 |
External Output | Alarm output (a contact: No-voltage resistive load 250V 2A) |
Display | LED RUN LED display / temperature error in the panel |
Regulatory Compliance | EN60335-1 EN60335-2-40/EN61000-6-2 EN61000-6-4 |
Environmental Response | RoHS |
Note: Cooling capacity 35 °C ambient temperature, the rated capacity of 35 °C when the set temperature inside the panel. Ambient humidity / ambient temperature (air enthalpy method measurement conditions JIS-C-9612) is not meant to satisfy all conditions in temperature and humidity. Rated value: 35 °C ambient temperature, ambient humidity RH 40% value at the time of use. RH 40% when the value of the maximum allowed ambient temperature, ambient humidity using an ambient temperature of use: The value MAX. The permissible ambient temperature: If you are in continuous use (less than 15 ~ 20 °C ambient), because there is a possibility of high-load operation of the compressor at low temperatures, the power supply is cut as much as possible please. Please read instructions carefully before use, please use properly. |
Parts list supplied
Mounting Bolt | 6 (M6 x L20) |
---|---|
Exhaust Hose | 2m |
INSULOK Tie | 1 |
Washer | 2 |
Spacer | 6 |
Wind Direction Louver | 1 |
Louvered Screw | 2 |
Gland | (Length) 2/ (short) 2 |
User Manual | 1 |
Maintenance Parts List
Internal Circulation Fan | Circulation fan for G1110L |
---|---|
External Fan | Air fan for G1110L |
Filter | ENC-F-21 * 2 |
Electrical Board | Substrate for G1110L/G1120L |