qm-9000d-sunghwa-detector-vietnam.png

QM-9000d Sunghwa Detector Vietnam, QM-9000d Sunghwa Detector Viet nam, QM-9000d Sunghwa Detector

Sunghwa Detector, Sunghwa Vietnam , Sunghwa Việt Nam , Sunghwa Detector Vietnam

FLAMMABLE & TOXIC GAS DETECTOR QM-9000D Series

Product Description

IR(Infrared) Gas Detector
■ 4~20mA.DC(Transmitter), RS-485 Modbus, HART Communication
■ FND LOCAL DIGITAL DISPLAY
■ MODEL : QM-9000D(IR)

FEATURES

◉ QM-9000D(IR) can continuously detect flammable gases, CO2, and CO.
◉ Providing a solution to measuring the optimal gas.
◉ QM-9000D(IR) is the highest quality gas detector used to measure target gases in real time in a place with potential toxic and flammable gases.
◉ Cutting-edge technology based on infrared ray measurement principle.
◉ Ensuring more than five-year stable lifetime.
◉ No malfunction due to the application of dedicated sensors.
◉ QM-9000D(IR) has the self-illuminating FND(LED) to identify atmospheric flammable concentrations even in a dark place.
◉ QM-9000D(IR) has a self-warning light at preset gas concentrations(6. LED, Event).
◉ Without opening its cover, its magnetic key and computer-based monitoring systems can adjust the zero point, control concentrations, correct temperatures, check the records of the latest calibration dates, and so on.
◉ The computer systems and controller function as a two-way transceiver for communication.
◉ Enclosure explosion-proof structure(IP66).

13_1

SPECIFICATION

| Model No. | QM-9000D(IR)
| Measuring gas | Flammable Gas – CH4, C2H2, etc. Toxic Gas – CO2, CO, N2O, etc.
| Measuring range | 0~100%(LEL) – Flammability 0~PPM, 0~%(Vol) – Toxicity(See the range of toxicity by gas)
| Measuring method | Diffusion Infrared type
| Measuring signal | 4~20mA.DC(Transmitter) Relay Contact(H.HH) or 24V.DC(H.HH) RS-485 Modbus/HART Communication – Option
| Measuring display | 4digit FND Digital & 4LED display(Power, Low, High, Fault) Warning, Flickering, Lighting
| Response time | Less than 5sec
| Transmission speed | 38,400bps
| Accuracy | ±3%/Full scale
| Operating Temp´/Humi´ | -40℃~+60℃/95% RH(Non-condensing)
| Operating power | 21~31V.DC
| Consumption electric power | 1.92W(4.56W During normal operation)
| Cable/Distance | UL-2919 1pair(RS-485 Communication), Supply 24V.DC/Max 1,000M CVVS(Shield) 1.5sq × 3wire(4~20mA.DC)/Max 2,500M
| Conduit connection cable | 3/4(22MM) PF, NPT
| Mounting type | Wall mounting or 2″ Pole mounting
| Approval | Ex d ⅡC T6(IP66) (KOSHA)
| Dimension | 126(W) × 241(H) × 126.1(D)
| Weight | 1.7Kgs