Compact, light weight flow meter for monitoring fuel consumption, differential type
Xuất sứ: Holland
Nhà cung cấp: PITESCO VIET NAM
Hãng sản xuất: Bronkhorst
FUEL-VIEW DFM-500D-K,
FUEL-VIEW DFM-250D-K,
FUEL-VIEW DFM-100D-K
Compact, light weight flow meter for monitoring fuel consumption, differential type
- Compact and lightweight
- Strong metal moulded case
- Ease of mounting and operation
- Very cost-effective solution
- Built-in fuel filter
- Stable to vibrations and hydraulic shock
The compact and light weight fuel flow meters for monitoring fuel consumption, differential type
FUEL-VIEW flow meters operate on the principle of a rotary piston that is mounted into a chamber ring which rotates in a chamber case. The rotating speed is measured by electronic sensors which measure a magnetic pulse. The number of pulses in time is proportional to the fuel flow rate. The unique design of the flow meter allows fuel flow, even if the chamber is locked or clogged up. A fuel filter effectively protects the measuring chamber from contamination and can be removed and washed without disassembling the flow meter.
FUEL-VIEW model DFM-500D-K can be used for 10...500 l/h. It is a differential fuel flow meters with a separate input and output connection for the supply and return line to measure the consumption of the fuel. The instrument has a cable for pulse output (with external power).
Technical specifications
Performance |
|
---|---|
Accuracy |
± 1...3% RD (depends on ratio of flow rate in forward chamber to flow rate in return chamber) |
Turndown |
1:50 (2...100%) |
Media |
Diesel fuel, gasoline*, petrol*, fuel oil, motor fuel, bio fuel. |
Repeatability |
<0.1% RD typical |
Operating pressure |
2...25 bar(a) |
Max. pressure drop |
<0.3 bar(d) at 20°C on diesel |
Operating temperature |
-40...80°C |
Humidity |
<95% at environmental temperature of 40°C |
Vibration |
Max. acceleration of 100 m/s2 in frequency range of 5...250 Hz |
Aggressive environment |
Resistant to fuel and lubricant material |
Mechanical parts |
|
---|---|
Material (wetted parts) |
O-ring: aluminium |
Housing |
Zinc-Aluminium alloy (ZA4) |
Ingress protection (housing) |
IP54 |
Connections |
R female M16 x 1.5 thread |
Electrical properties |
|
---|---|
Output |
scaled pulse: 20 ml/pulse; |
External power supply |
+10…50 Vdc |
Current consumption |
for 12 Vdc - 50 mA |
Electrical connection |
interface cable with plug connection |