Brauntacho Vietnam, Protection systems, Single Channel for 1oo1, 1oo2 and 2oo2 solutions, Triple Channel (TMR) for 2oo3 solutions, OEM specific Protection Systems, Brauntacho Việt Nam
Nhà cung cấp: Pisteco Việt Nam
Hãng sản xuất: BraunTacho, Braun Tacho Vietnam
E16 System product matrix (overview), Standard solutions in 2oo3 architecture
Model | SIL3 | SIL2 | PFD Value | Test Interface |
Test Generator |
Automatic Test of 2oo3 Solenoid by E16 |
PROFIBUS Interface |
E16x342 | ● | 7,71 · 10-5 | ● | 1 | |||
E16x352 | ● | 7,71 · 10-5 | ● | 2 | |||
E16x346 | ● | 8,41 · 10-6 | ● | ● | 1 | ||
E16x356 | ● | 8,41 · 10-6 | ● | ● | 2 | ||
E16x442 | ● | 1,81 · 10-4 | ● | 1 | |||
E16x452 | ● | 1,81 · 10-4 | ● | 2 | |||
E16x446 | ● | 2,51 · 10-5 | ● | ● | 1 | ||
E16x456 | ● | 2,51 · 10-5 | ● | ● | 2 |
Protection Systems for highest safety requirements up to SIL 3
E16x342
Monitoring and Protection System E16x342 for highest safety requirements up to SIL3
- TMR (triple-modular-redundant) system with sensor monitoring and self-test
- Highest safety levels with maximum availability by globally unique and true 2oo3 architecture for each trip criterion within each of the three Monitors
- Maintenance-free during lifetime due to integrated automatic proof tests
- External test of a 2oo3 solenoid valve block possible via the control system
- Minimal Total Cost of Ownership
- Requires less than 8% of the permissible PFD value for a SIL3 Safety Loop
- Replacement of all active components during operation (Hot Swap)
- TÜV certified for SIL3 / IEC 61508:2010
- TÜV certified for PL e; Cat. 3 / DIN EN ISO 13849-1:2008
- TÜV certified for SILCL3 / IEC 62061:2005
- API670 and API612 compliant
- 1 PROFIBUS Interface
E16x352
Monitoring and Protection System E16x352 for highest safety requirements up to SIL3
- TMR (triple-modular-redundant) system with sensor monitoring and self-test
- Highest safety levels with maximum availability by globally unique and true 2oo3 architecture for each trip criterion within each of the three Monitors
- Maintenance-free during lifetime due to integrated automatic proof tests
- External test of a 2oo3 solenoid valve block possible via the control system
- Minimal Total Cost of Ownership
- Requires less than 8% of the permissible PFD value for a SIL3 Safety Loop
- Replacement of all active components during operation (Hot Swap)
- TÜV certified for SIL3 / IEC 61508:2010
- TÜV certified for PL e; Cat. 3 / DIN EN ISO 13849-1:2008
- TÜV certified for SILCL3 / IEC 62061:2005
- API670 and API612 compliant
- 2 PROFIBUS Interfaces
E16x346
Monitoring and Protection System E16x346 for highest safety requirements up to SIL3
- TMR (triple-modular-redundant) system with sensor monitoring and self-test
- Highest safety levels with maximum availability by globally unique and true 2oo3 architecture for each trip criterion within each of the three Monitors
- Maintenance-free during lifetime due to integrated automatic proof tests
- Automated tests of a 2oo3 solenoid valve block with permanent monitoring of the feedback via the test generator
- Minimal Total Cost of Ownership
- Requires less than 1% of the permissible PFD value for a SIL3 Safety Loop
- Enhanced safety values due to an integrated test generator
- Replacement of all active components during operation (Hot Swap)
- TÜV certified for SIL3 / IEC 61508:2010
- TÜV certified for PL e; Cat. 3 / DIN EN ISO 13849-1:2008
- TÜV certified for SILCL3 / IEC 62061:2005
- API670 and API612 compliant
- 1 PROFIBUS Interface
E16x356
Monitoring and Protection System E16x356 for highest safety requirements up to SIL3
- TMR (triple-modular-redundant) system with sensor monitoring and self-test
- Highest safety levels with maximum availability by globally unique and true 2oo3 architecture for each trip criterion within each of the three Monitors
- Maintenance-free during lifetime due to integrated automatic proof tests
- Automated tests of a 2oo3 solenoid valve block with permanent monitoring of the feedback via the test generator
- Minimal Total Cost of Ownership
- Requires less than 1% of the permissible PFD value for a SIL3 Safety Loop
- Enhanced safety values due to an integrated test generator
- Replacement of all active components during operation (Hot Swap)
- TÜV certified for SIL3 / IEC 61508:2010
- TÜV certified for PL e; Cat. 3 / DIN EN ISO 13849-1:2008
- TÜV certified for SILCL3 / IEC 62061:2005
- API670 and API612 compliant
- 2 PROFIBUS Interfaces
E16x442
Monitoring and Protection System E16x442 for increased safety requirements up to SIL2
- TMR (triple-modular-redundant) system with sensor monitoring and self-test
- Highest safety levels with maximum availability by globally unique and true 2oo3 architecture for each trip criterion within each of the three Monitors
- Maintenance-free during lifetime due to integrated automatic proof tests
- External test of a 2oo3 solenoid valve block possible via the control system
- Minimal Total Cost of Ownership
- Requires less than 8% of the permissible PFD value for a SIL2 Safety Loop
- Replacement of all active components during operation (Hot Swap)
- SIL2 / IEC 61508:2010 compliant
- API670 and API612 compliant
- 1 PROFIBUS Interface
E16x452
Monitoring and Protection System E16x452 for increased safety requirements up to SIL2
- TMR (triple-modular-redundant) system with sensor monitoring and self-test
- Highest safety levels with maximum availability by globally unique and true 2oo3 architecture for each trip criterion within each of the three Monitors
- Maintenance-free during lifetime due to integrated automatic proof tests
- External test of a 2oo3 solenoid valve block possible via the control system
- Minimal Total Cost of Ownership
- Requires less than 8% of the permissible PFD value for a SIL2 Safety Loop
- Replacement of all active components during operation (Hot Swap)
- SIL2 / IEC 61508:2010 compliant
- API670 and API612 compliant
- 2 PROFIBUS Interfaces
E16x446
Monitoring and Protection System E16x446 for increased safety requirements up to SIL2
- TMR (triple-modular-redundant) system with sensor monitoring and self-test
- Highest safety levels with maximum availability by globally unique and true 2oo3 architecture for each trip criterion within each of the three Monitors
- Maintenance-free during lifetime due to integrated automatic proof tests
- Automated tests of a 2oo3 solenoid valve block with permanent monitoring of the feedback via the test generator
- Minimal Total Cost of Ownership
- Requires less than 1% of the permissible PFD value for a SIL2 Safety Loop
- Enhanced safety values due to an integrated test generator
- Replacement of all active components during operation (Hot Swap)
- SIL2 / IEC 61508:2010 compliant
- API670 and API612 compliant
- 1 PROFIBUS Interface
E16x456
Monitoring and Protection System E16x456 for increased safety requirements up to SIL2
- TMR (triple-modular-redundant) system with sensor monitoring and self-test
- Highest safety levels with maximum availability by globally unique and true 2oo3 architecture for each trip criterion within each of the three Monitors
- Maintenance-free during lifetime due to integrated automatic proof tests
- Automated tests of a 2oo3 solenoid valve block with permanent monitoring of the feedback via the test generator
- Minimal Total Cost of Ownership
- Requires less than 1% of the permissible PFD value for a SIL2 Safety Loop
- Enhanced safety values due to an integrated test generator
- Replacement of all active components during operation (Hot Swap)
- SIL2 / IEC 61508:2010 compliant
- API670 and API612 compliant
- 2 PROFIBUS Interfaces