brauntacho-vietnam-hall-effect-sensors-ex-ia-intrinsically-safe-bo-cam-bien-hieu-ung-toc-do-brauntacho.png

Differential-Hall-Effect Speed Sensors Ex ia (intrinsically safe) Series A5S1

A5S1DD0

Sensor A5S1DD0 for detection of rotational speed in Hazardous Areas Zone 0 or 1

  • Contact-free, wear-free, maintenance-free
  • Unsusceptible versus external magnetic stray fields and machine vibration
  • Suitable for all applications where high levels of accuracy and reliability are at a premium
  • Frequency range 0 Hz...25 kHz
  • Single Channel, the output displays the rotational speed as a single track frequency signal
  • TÜV certified for safety level SIL3 / IEC 61508:2010
  • TÜV certified for PL e; Cat. 3 / DIN EN ISO 13849-1:2016 + DIN EN ISO 13849-2:2012
  • TÜV certified for SILCL3 / IEC 62061:2015
  • Requires Isolating Barrier D461
  • For installation in Hazardous Areas as intrinsically safe operating resource
    • ATEX/IECEx certified for Ex ia IIC T4/T6 Ga
    • UL/CSA certified for Class I, Div 1, Groups A, B, C, D
    • EAC certified for Ex ia IIC T4/T6 Ga

A5S1DD3

Sensor A5S1DD3 for detection of rotational speed and direction of rotation in Hazardous Areas Zone 0 or 1

  • Contact-free, wear-free, maintenance-free
  • Unsusceptible versus external magnetic stray fields and machine vibration
  • Suitable for all applications where high levels of accuracy and reliability are at a premium
  • Frequency range 0 Hz...25 kHz
  • Dual Channel, 1 track = rotational speed as frequency, 1 track = F/R status as binary signal
  • TÜV certified for safety level SIL3 / IEC 61508:2010
  • TÜV certified for PL e; Cat. 3 / DIN EN ISO 13849-1:2016 + DIN EN ISO 13849-2:2012
  • TÜV certified for SILCL3 / IEC 62061:2015
  • Requires Isolating Barrier D461
  • For installation in Hazardous Areas as intrinsically safe operating resource
    • ATEX/IECEx certified for Ex ia IIC T4/T6 Ga
    • UL/CSA certified for Class I, Div 1, Groups A, B, C, D
    • EAC certified for Ex ia IIC T4/T6 Ga

A5S1DD4

Sensor A5S1DD4 for detection of rotational speed and direction of rotation with two phase-shifted speed signals in Hazardous Areas Zone 0 or 1

  • Contact-free, wear-free, maintenance-free
  • Unsusceptible versus external magnetic stray fields and machine vibration
  • Suitable for all applications where high levels of accuracy and reliability are at a premium
  • Frequency range 0 Hz...25 kHz
  • Dual Channel, the output displays the rotational speed as a twin-track frequency signal (phase shifted)
  • Suitable for external direction detection with enhanced safety
  • TÜV certified for safety level SIL3 / IEC 61508:2010
  • TÜV certified for PL e; Cat. 3 / DIN EN ISO 13849-1:2016 + DIN EN ISO 13849-2:2012
  • TÜV certified for SILCL3 / IEC 62061:2015
  • Requires Isolating Barrier D461
  • For installation in Hazardous Areas as intrinsically safe operating resource
    • ATEX/IECEx certified for Ex ia IIC T4/T6 Ga
    • UL/CSA certified for Class I, Div 1, Groups A, B, C, D
    • EAC certified for Ex ia IIC T4/T6 Ga

A5S1DS0

Sensor A5S1DS0 for detection of rotational speed in Hazardous Areas Zone 0 or 1

  • Contact-free, wear-free, maintenance-free
  • Unsusceptible versus external magnetic stray fields and machine vibration
  • Suitable for all applications where high levels of accuracy and reliability are at a premium
  • Frequency range 0 Hz...12 kHz
  • Single Channel, the output displays the rotational speed as a single track frequency signal
  • TÜV certified for safety level SIL3 / IEC 61508:2010
  • TÜV certified for PL e; Cat. 3 / DIN EN ISO 13849-1:2016 + DIN EN ISO 13849-2:2012
  • TÜV certified for SILCL3 / IEC 62061:2015
  • Requires Isolating Barrier D461
  • For installation in Hazardous Areas as intrinsically safe operating resource
    • ATEX/IECEx certified for Ex ia IIC T4/T6 Ga
    • UL/CSA certified for Class I, Div 1, Groups A, B, C, D
    • EAC certified for Ex ia IIC T4/T6 Ga

A5S1DS3

Sensor A5S1DS3 for detection of rotational speed and direction of rotation in Hazardous Areas Zone 0 or 1

  • Contact-free, wear-free, maintenance-free
  • Unsusceptible versus external magnetic stray fields and machine vibration
  • Suitable for all applications where high levels of accuracy and reliability are at a premium
  • Frequency range 0 Hz...12 kHz
  • Dual Channel, 1 track = rotational speed as frequency, 1 track = F/R status as binary signal
  • TÜV certified for safety level SIL3 / IEC 61508:2010
  • TÜV certified for PL e; Cat. 3 / DIN EN ISO 13849-1:2016 + DIN EN ISO 13849-2:2012
  • TÜV certified for SILCL3 / IEC 62061:2015
  • Requires Isolating Barrier D461
  • For installation in Hazardous Areas as intrinsically safe operating resource
    • ATEX/IECEx certified for Ex ia IIC T4/T6 Ga
    • UL/CSA certified for Class I, Div 1, Groups A, B, C, D
    • EAC certified for Ex ia IIC T4/T6 Ga

A5S1DS4

Sensor A5S1DS4 for detection of rotational speed and direction of rotation with two phase-shifted speed signals in Hazardous Areas Zone 0 or 1

  • Contact-free, wear-free, maintenance-free
  • Unsusceptible versus external magnetic stray fields and machine vibration
  • Suitable for all applications where high levels of accuracy and reliability are at a premium
  • Frequency range 0 Hz...12 kHz
  • Dual Channel, the output displays the rotational speed as a twin-track frequency signal (phase shifted)
  • Suitable for external direction detection with enhanced safety
  • TÜV certified for safety level SIL3 / IEC 61508:2010
  • TÜV certified for PL e; Cat. 3 / DIN EN ISO 13849-1:2016 + DIN EN ISO 13849-2:2012
  • TÜV certified for SILCL3 / IEC 62061:2015
  • Requires Isolating Barrier D461
  • For installation in Hazardous Areas as intrinsically safe operating resource
    • ATEX/IECEx certified for Ex ia IIC T4/T6 Ga
    • UL/CSA certified for Class I, Div 1, Groups A, B, C, D
    • EAC certified for Ex ia IIC T4/T6 Ga

D461R1

Isolating Barrier D461R1 for A5S1... Ex ia sensors in Hazardous Areas Zone 0-1

  • For use in connection with A5S1... Ex ia series sensors a highly efficient system for detecting rotational speed (and direction of rotation) in areas of explosion risk
  • Provides intrinsic safety for the sensor and its cabling
  • Enhanced output signal for use by electronic measuring devices
  • Implementation outside the Hazardous Area, resp. protected by a pressure resistant encapsulated housing
  • Certification
    • ATEX as Ex ia Ga IIC
    • IECEx as Ex ia Ga IIC
    • EAC as Ex ia Ga IIC