Unipulse Vietnam, ATW200, ULE-50, PS-IA-HS, PS-IA, PS-Ⅲ, đại lý Unipulse Vietnam

 

The true high speed displacement (not the integral value of the velocity) measurement up to 3MHz bandwidth.
Easy operation that only closing the sensor probe to the target surface.
The calibration of the surface reflectivity is not required.
Features of ATW200
  • Fast response up to 3MHz bandwidth! Best suited for ultrasonic vibrator and high-frequency vibration measurement.
  • Extra-high resolution for the nanometer measurement capability! Since it is truly for displacement measurement, rather than speed measurement, even a small displacement at low frequency can be detected as well.
  • The variable low-pass filter is available! The ideal balance between the high response speed and high resolution can be achieved.
  • Easy setup! By putting sensor near the target, only one time is needed for calibration of reflectance.
Principle of ATW200

ATW200 is a differential fiber-optic displacement sensor! With our unique arrangement of optic fibers (patent granted), nanometer-order resolution and responsiveness of 3 MHz are achieved, and influence by reflectance of the measured target is suppressed.

As shown in Figure 1, fiber optic bundle is splitted into 3 branches, each connecting to the opposite side of the illuminating fiber, light receiving fiber A and light receiving fiber B placed at the measurement terminal. When the light from light source is projected diagonally onto the illuminating fiber, the light will be reflected from the suface of measuring object as shown in Figure 2 onto the light receiving fiber. At that moment, the reflected light will form a ring shape, and its diameter varies according to the measurement gap. The amount of light projected onto the light receiving fiber is labeled as PA and PB, and the changes are shown in Figure 3. In Figure 4, the sum of signal PA+PB is the total light reflected, whereas the difference between signal PB-PA changes according to the gap. The signal obtained through division of the difference and sum signals is irrelevant to the reflectance of the measuring object. (Figure 5)

Application example

Ideal for the high-speed micro-displacement measurement (e.g. scanning probe microscope cantilever, piezoelectric elements, LCD glass, vibration analysis of glass disk, etc…).

 

Specifications

Amplification unitPlug-in moduleResolution example

Amplification unit
Model ATW200
Principle Differential fiber-optic type
Responsivity(Hz)
Available response frequency
100, 1K, 10K, 100K, 1M, PASS (3M)
Variable magnification

×1, ×2, ×5, ×10,×20, ×50

Display 4 and 1/2 digit digital voltage meter
Analog output ±10VDC
Operating voltage AC 100V 50/60Hz or DC24V 1.2A
Operating conditions 0 to 45℃ 20 to 85%RH (non-condensation)